เครื่องโฟโตมิเตอร์-ไนเตรท (Nitrate Photometer 0.0- 100 mg/L)

HI 93828

Nitrate Photometer with 555 nm LED

          Nitrates are present in nature as a result of decomposition of organic microorganisms or due to their use as fertilizers. Nitrates reduce to nitrites, which in turn easily combine to form substances dangerous to man.

A maximum level of 45 mg/L is established as a worldwide guideline for nitrate concentration in water. In Europe, the maximum consented level of nitrates in potable water is 50.0 mg/L, while in the USA the EPA has established a guideline for the maximum level of nitrate nitrogen of 10 mg/L (NO-³-N), which corresponds to 45.0 mg/L of nitrates.

The HANNA® solutions are HI 93728 and HI 93828, hand held meters suited for field measurement. Reading procedures have been made as simple as possible to allow everyone to perform accurate nitrate measurements.

The kit provides you with all you need for field measurement: photometer, reagents and apparatus perfectly fitted in a rugged carrying case

• HI 93728 reads nitrogen nitrate from 0 to 30 mg/L (NO-³-N); multiply the readout by a factor of 4.43 and you can read up to 133 mg/L of nitrate (NO-³).
• HI 93828 reads nitrate directly in mg/L of NO-³, from 0 to 100 mg/L.

With a normal 9V battery you will be able to get more than 300 measurements. The auto shut-off feature (after 10 minutes of non-use) guarantees a long battery life.

Order Information:
HI 93828 is supplied with 2 cuvets, battery and instructions.
**Add “C” to end of Product Code for the kit which includes a hard carrying case and reagents.

Specifications

Range   0.0 to 100 mg/L (NO³)
Resolution   1 mg/L
Accuracy   ±5 mg/L ±5% of reading
Light Source   LED 555 nm
Light Life   Life of the instrument
Light Detection   Silicon Photocell
Battery Type / Life   1 x 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
Weight   290 g (10 oz.)
Method   Adaptation of cadmium reaction method. The reaction between
nitrate-nitrogen and the reagent causes an amber tint in the sample

Accessories

Solutions

HI 93703-50 Solution for Cleaning Cuvets

Accessories

HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
HI 731325 Cuvet Cap Turbidity Meters & HI 937xx Series Meters
HI 710009 Shockproof Boot, Blue
HI 710010 Shockproof Boot, Orange
HI 731318 Tissue for Wiping Cuvets
Reagents & Standards
HI 93728-01 Nitrate, Cadmium Reduction Method (100 Tests)
HI 93728-03 Nitrate, Cadmium Reduction Method (300 Tests)

 

ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • สนใจขอใบเสนอราคาและสั่งซื้อสินค้า

    บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
    131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 
    ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
    โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929 


    คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653

    E-mail : info@highents.com , IDline: @alltestkit

     

    >> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<