เครื่องโฟโตมิเตอร์-เหล็ก (Iron Checker 0.00-5.00 ppm.)

HI 721

Iron Range: 0.00 to 5.00 ppm(mg/L)

Easier to use and more accurate than chemical test kits

Phenanthroline method Accuracy ±0.04 ppm (mg/L) ±2% of reading 0.01 ppm (mg/L) resolution (250 points)Large, easy to read digits Auto shut-off.

Dedicated to a single parameter

Designed to work with HANNA’s powder reagents Uses 10 mL glass cuvettes.

Small Size, Big Convenience

Weighing a mere 65g (2.3 oz.), the Checker®HC easily fits into the palm of your hand or pocket.Use for quick and accurate on the spot analysis.Single button operation: Zero and Measure Operated by a single AAA battery.

Ideal for

Industrial, ground and treated waters, mining leachate monitoring and agricultural irrigation water.

ACCURATE AND AFFORDABLE IRON MEASUREMENT

About 6.3% of the earths crust is made of iron, of which 43% is in soils. The analysis of iron is often performed to monitor ground water and irrigation waters as a gauge of corrosion from industrial settling, and as an indication of the effectiveness of treatment from mining leachate. The HANNA HI 721 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain.

The HANNA HI 721 Checker®HC is accurate and affordable with immediate results. The new HI 721 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and 2% ±0.04 ppm accuracy of reading. The HI 721 Checker®HC uses an adaptation of Standard Method 3500-Fe B. The contoured style of this Checker®HC fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off. The HI 721 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagent. Last, Place the vial into the HI 721 Checker®HC, press the button and read the results. It’s that easy.

Specifications

Range   0.00 to 5.00 ppm (mg/L)
Resolution   0.01 ppm (mg/L)
Precision   2% of reading ±0.04 ppm (mg/L) @ 25°C
Light Source   LED @ 525 nm
Light Detector   Silicon photocell
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   After 2 minutes of non-use and after read
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight   64 g (2.25 oz.)
Method   Adaptation of Standard Method 3500-Fe B.

Accessories

HI 731321 Glass Cuvet for HI 937xx & HI 832xx Series Meters
HI 731318 Tissue for Wiping Cuvets
HI 731225 Caps for cuvet
HI 93703-50 Solution for Cleaning Cuvets
Reagents & Standards
HI 721-11 Standard for Iron Checker HC
HI 721-25 Reagents for 25 test (Iron)

 

ไฟล์ที่เกี่ยวข้องกับผลิตภัณฑ์
  • สนใจขอใบเสนอราคาและสั่งซื้อสินค้า

    บริษัท ไฮเออร์ เอ็นท์เตอร์ไพรส์ จำกัด
    131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 
    ต. คลองหลวง อ.คลองหลวง จ. ปทุมธานี 12120
    โทร. 081-847-6768, 02-191-3928 แฟ็กซ์. 02-191-3929 


    คุณโทณิวัฒน์ 085-811-4779 , คุณนารีรัตน์ 085-814-9653

    E-mail : info@highents.com , IDline: @alltestkit

     

    >> ขอใบเสนอราคาแบบออนไลน์ คลิก !! <<